Pure water producing equipment for the pharmaceutical industry 制药医药行业需要通过GMP认证,所以对水质有固定要求,则电导率≤2μs/cm 2.25℃或电导率≤0.2 μs/cm 2.25℃:那么根据GMP相关要求,和客户原水水质情况可采用:多介质过滤器,活性炭过滤器,一级微孔保护过滤,二级微孔保护过滤,阻垢,一级反渗透,中间罐,加药装置,二级反渗透装置,紫外线~,成品水罐输送。也有采用上述工艺再加可再生混床,紫外线二级~,到成品水罐,输送。客户可跟自己客观条件和用水要求进行选择。 Pharmaceutical industry needs to pass the GMP certification, so there are stable requirements on water quality, Conductivity is ≤2μs/cm 2.25℃ or conductivity ≤0.2 μs/cm 2.25℃: so according to GMP requirements, and customer’s raw water quality, can adopt: multi- media filter, activated carbon filter, microporous filter, stage Ⅱmicroporous filter, scale inhibitor, reverse osmosis, middle tank, dosing device, stage Ⅱ reverse osmosis device, the ultraviolet sterilization, produced water tank to transport. Also you can add regenerative mixed bed, ultraviolet sterilization to finished water tank to transport. The customer can choose the equipments as the objective conditions and water quality request. |